To adjust the distance between the labeling cylinder and the stripping cylinder, start by closing the pneumatic valve. Then, pull down the labeling cylinder to its limit position and observe the space between the platform plane of the cylinder and the bottom surface of the suction head. Carefully adjust the position of the cylinder until the platform plane is positioned slightly lower than the suction head's bottom surface. You can adjust the cylinder's height by loosening the fixing plate and tightening it again after making the necessary adjustment. Ensure to lock the fixing plate tightly to guarantee the cylinder's stability.
To ensure that the stripping cylinder platform and suction head are properly matched, you need to make some adjustments. Firstly, turn off the pneumatic valve and remove the label stripping cylinder. Next, lower the suction head and observe whether the label is accurately absorbed by the suction head, and whether it is correctly positioned on the label stripping cylinder platform. It is important to note that the label suction position should only be crossed with one label. If you find that the suction head is not accurately positioned on the platform or if two labels are present on the suction position, it is necessary to adjust the limit screw on the label stripping cylinder. If the adjustment range is limited, then simply adjust the suction head's position accordingly. By making these precise adjustments, you can ensure that the equipment functions smoothly and labels are applied accurately.
The installation of the label is crucial and must be done carefully. The label should be neatly wrapped without any creases. If the label is not aligned properly, it may easily break. Once the label is installed, make sure to fix the position with the stop ring.
When preparing to label products using a labeling machine, it is crucial to adjust the upper and lower cylinders before beginning the process. Firstly, place the item to be labeled onto the fixture, then shut the pneumatic valve. After this, pull down the labeling cylinder as well as the labeling upper and lower cylinders to the limit position. Carefully observe the suction head to ensure it can effectively press the labeling position onto the surface of the product. If the touch point of the label is not in contact with the product surface, it is necessary to adjust the fixing plate of the upper and lower cylinders of the label. This can be done by loosening the screw and adjusting the fixture platform. However, it is vital to note that different products may require varying pressing degrees of the suction head. For planar labels, it is adequate for the suction head to only make contact with the product's surface. In comparison, for arc surface labeling, the suction head needs a little more pressure to guarantee a complete label covering. Lastly, for concave items, it is necessary to utilize corresponding suction head clamps to attach the label correctly.
Label stripping length adjustment is vital, and it depends on the size of the labels being used. Larger labels require a peeled out 1/3 of a specific length, whereas smaller labels only need an edge of 1-3 mm. The label stripping length can be adjusted by taking note of the spacing of the mobile marker eye. If the stripping length is insufficient, move the marker eye to the left. Conversely, if the length of the label is too long, move the marker eye to the right. Therefore, it is essential to adjust label stripping lengths accordingly, as it aids in ensuring that the labels are appropriately placed.
To ensure efficient vacuum cleaning, it's essential to adjust the suction force accordingly. In cases where the suction force is not up to par, it's possible to increase the force by blocking other unnecessary holes on the suction head. Additionally, you can wrap the gap at the edge of the suction head with raw material tape to avoid air leakage. With these adjustments, you can improve the suction force at the suction position, ensuring your vacuum cleaner efficiently picks up dirt and debris.